| Product characteristics | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Output signal | switching signal; analog signal; (configurable) | ||||||||||
| Measuring range |
|
||||||||||
| Process connection | threaded connection G 1/4 Internal thread | ||||||||||
| Application | |||||||||||
| System | gold-plated contacts | ||||||||||
| Application | for industrial applications | ||||||||||
| Media | liquids and gases | ||||||||||
| Cannot be used for | oils | ||||||||||
| Medium temperature [°C] | -25…80 | ||||||||||
| Min. bursting pressure |
|
||||||||||
| Pressure rating |
|
||||||||||
| Type of pressure | relative pressure | ||||||||||
| Electrical data | |||||||||||
| Operating voltage [V] | 18…36 DC; (according to EN 50178 SELV/PELV) | ||||||||||
| Current consumption [mA] | < 50 | ||||||||||
| Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||||
| Protection class | III | ||||||||||
| Reverse polarity protection | yes | ||||||||||
| Overvoltage protection | yes; (< 40 V) | ||||||||||
| Power-on delay time [s] | 0.3 | ||||||||||
| Integrated watchdog | yes | ||||||||||
| Inputs / outputs | |||||||||||
| Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 | ||||||||||
| Outputs | |||||||||||
| Total number of outputs | 2 | ||||||||||
| Output signal | switching signal; analog signal; (configurable) | ||||||||||
| Electrical design | PNP | ||||||||||
| Number of digital outputs | 1 | ||||||||||
| Output function | normally open / closed; (configurable) | ||||||||||
| Max. voltage drop switching output DC [V] | 2 | ||||||||||
| Permanent current rating of switching output DC [mA] | 250 | ||||||||||
| Switching frequency DC [Hz] | < 170 | ||||||||||
| Number of analog outputs | 1 | ||||||||||
| Analog current output [mA] | 4…20; (0 bar = 4 mA; 10 bar = 20 mA) | ||||||||||
| Max. load [Ω] | 500 | ||||||||||
| Analog voltage output [V] | 0…10; (0 bar = 0 V; 10 bar = 10 V) | ||||||||||
| Min. load resistance [Ω] | 2000 | ||||||||||
| Short-circuit protection | yes | ||||||||||
| Type of short-circuit protection | yes (non-latching) | ||||||||||
| Measuring/setting range | |||||||||||
| Measuring range |
|
||||||||||
| Set point SP |
|
||||||||||
| Reset point rP |
|
||||||||||
| In steps of |
|
||||||||||
| Factory setting |
|
||||||||||
| Accuracy / deviations | |||||||||||
| Switch point accuracy [% of the span] | < ± 0,5 | ||||||||||
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | ||||||||||
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | ||||||||||
| Hysteresis deviation [% of the span] | < ± 0,25 | ||||||||||
| Long-term stability [% of the span] | < ± 0,05; (per 6 months) | ||||||||||
| Temperature coefficient zero point [% of the span / 10 K] | 0,2; (-20…80 °C) | ||||||||||
| Temperature coefficient span [% of the span / 10 K] | 0,2; (-20…80 °C) | ||||||||||
| Reaction times | |||||||||||
| Delay time programmable dS, dr [s] | 0; 0,2…50 | ||||||||||
| Max. response time analog output [ms] | 3 | ||||||||||
| Software / programming | |||||||||||
| Parameter setting options | hysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output | ||||||||||
| Operating conditions | |||||||||||
| Ambient temperature [°C] | -20…80 | ||||||||||
| Storage temperature [°C] | -40…100 | ||||||||||
| Protection | IP 67 | ||||||||||
| Tests / approvals | |||||||||||
| EMC |
|
||||||||||
| Shock resistance |
|
||||||||||
| Vibration resistance |
|
||||||||||
| MTTF [years] | 231 | ||||||||||
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | ||||||||||
| Mechanical data | |||||||||||
| Weight [g] | 260.5 | ||||||||||
| Material | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE | ||||||||||
| Materials (wetted parts) | stainless steel (1.4404 / 316L); ceramics (99.9 % Al2O3); Sealing of the measuring cell: EPDM | ||||||||||
| Min. pressure cycles | 100 million | ||||||||||
| Process connection | threaded connection G 1/4 Internal thread | ||||||||||
| Displays / operating elements | |||||||||||
| Display |
|
||||||||||
| Remarks | |||||||||||
| Pack quantity | 1 pcs. | ||||||||||
| Electrical connection | |||||||||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||||||||




Đánh giá
Chưa có đánh giá nào.